Gå til innhold
  • Bli medlem
Støtt hjemmeautomasjon.no!

Søk i nettsamfunnet

Viser resultater for emneknaggene 'obis'.

  • Søk etter emneknagger

    Skriv inn nøkkelord separert med kommaer.
  • Søk etter forfatter

Innholdstype


Kategorier

  • Generelt
    • Automasjonskaféen
    • Annen Elektronikk
    • Ditt system
    • Grafikk og design
    • Nettverk
    • Nybegynner
  • Bruksområder
    • A/V-kontroll
    • Belysning
    • Klimakontroll
    • Overvåking
    • Sikkerhet
    • Strømsparing og strøm-overvåkning
    • Talestyring
  • Systemer
    • Domoticz
    • Fibaro Home Center
    • Futurehome
    • HDL
    • Home Assistant
    • HomeKit
    • HomeSeer
    • Homey
    • Indigo Domotics
    • Node-Red
    • openHAB
    • Sensio
    • SmartThings
    • Telldus Live!
    • Vera
    • Z-Way
    • Zipato
    • Øvrige systemer
  • Teknologi / Protokoller
    • Blåtann
    • irDA
    • KNX
    • Mikrokontrollere
    • MQTT
    • RF
    • xComfort
    • Z-Wave
    • ZigBee
  • Utlån, kjøp og salg
    • Prisjakt
    • Kjøp / Salg
    • Powerbuy
    • Kommersielle tilbud
    • Utlån
  • Nettstedet
    • Kunngjøringer
    • Nyheter
    • Ris, ros og spørsmål om forumet

Blogger

  • En teknologisk hverdag
  • Enda en hobby?
  • Smånytt
  • en guide til elektro-verdenen

Kategorier

  • Filer
  • HomeSeer
  • Z-Wave

Kategorier

  • Nyheter
    • Produkter
    • Programvare
  • Tester
    • Systemer
  • Guider
    • Fibaro
    • HomeSeer
    • Nettverk
    • openHAB
    • Z-Wave
    • ESP32

Kategorier

  • Regler

Kalendre

  • Eventerer

Product Groups

Ingen resultater.


Finn resultater i...

Finn resultater som inneholder...


Startdato

  • Start

    Slutt


Sist oppdatert

  • Start

    Slutt


Filtrer etter antall...

Ble med

  • Start

    Slutt


Gruppe


Om meg


System

Fant 1 resultat

  1. Jeg har en Kamstrup AMS fra Norgesnett med åpen HAN-port. For å lese disse DLMS OBIS datapush-meldingene har jeg en USB-til-MBUS-slave-modul koblet til en Raspberry Pi. Jeg skrev noen få linjer med Python for å skrive ut meldingene som kommer, og dette ser i utgangspunktet ut til å fungere stabilt og som forventet. Det jeg lurer på er om noen kan hjelpe meg å tyde/forklare meldingene til meg, fordi de later til å være mye kortere (145-160 bytes) enn det jeg har sett eksempler på her på forumene. Etter å ha lest hundrevis av meldinger og side opp og side ned her inne + lest kode og eksempeldata på spesielt https://github.com/roarfred/AmsToMqttBridge/ så skjønner jeg bare ikke hva det er med meldingene jeg får. Meldingene kommer hvert 10. sekund som forventet, og hver time kommer det en bittelitt lenger melding (den også mye kortere enn forventet). Det er som om OBIS-kodene ikke er med i meldingene. Start og slutt med byten E7 er alltid til stede og CRC for hvertfall header har stemt de gangene jeg har sjekket den. Her er eksempler på noen meldinger jeg får: 2019-01-20T21:50:11.195980 - 155 bytes: 7EA0E22B2113239AE6E7000F0000F8BF60D9509126A18000F0FF682A566B1797AE17AE650582828A4A641428FE0A1135372036353627323132343834373536090601017CF10A1236383431313331424E323433313031303430090681F9FF0680FFFBFE06C006E006F089C7FE74080600F80906F13AC60600FC4A6414DF100600FC89C7FE12C0BD4250B8FF3BE61200EB090601E1901200EB11CB7E 2019-01-20T21:50:21.194220 - 154 bytes: 7EA0E22B2113239AE6E7000F0000F8BF60D9509126D18000F0FF682A566B1797AE17AE650582828A4A641428FE0A1135372036353627323132343834373536090601017CF10A1236383431313331424E323433313031303430090681F9FF0680FFFFFF06C006E006F00906F17408FF0600F85F2150FE3AC40600FC4B7FDF07FC0600FCFF12C02FC8505807FC1200EC090601F1D81200EE88D47E 2019-01-20T21:50:31.194745 - 154 bytes: 7EA0E22B2113239AE6E7000F0000F8BF60D9509126F4800080FBB6FE682A566B1797AE17AE650582828A4A641428FE0A1135372036353627323132343834373536090601017EF10A1236383431313331424E323433313031303430090681F9FF0680FF06C006E006F00906C1FF7408FF0600F85F2150FE3AC40600FC4B7FDF07FC0600FC12C02FC8505CFF07FC1200EC090601F1D81200EE13D47E 2019-01-20T21:50:41.189758 - 156 bytes: 7EA0E22B2113239AE6E7000F0000F8BF60D9509126A58000F0FF682A566B1797AE17AE650582828A4A641428FE0A1135372036353627323132343834373536090601017CF10A1236383431313331424E323433313031303430090681F9FF0680FF96C828FF06C0FF06E006F089C7FE74080600F80906F13AC40600FC4A6414DF100600FCFF12C02FC85058FF3BE61200EC090601F1D81200EB3DC07E Hvis jeg tar f.eks. den siste meldingen over og bruker mye av kunnskapen fra https://github.com/roarfred/AmsToMqttBridge/blob/master/Samples/Kamstrup/readme.md og https://github.com/roarfred/AmsToMqttBridge/blob/master/Samples/Kamstrup/obisdata.md så tolker jeg det som noe slikt som under. Jeg har brukt linjeskift ved de typiske separatorene bare for å prøve å finne mønster, men det vil nok ofte være helt feil ettersom jeg ofte ikke får ting til å stemme med "02 - one byte following 06 - long (4 bytes / 32 bits) 12 - int (2 bytes / 16 bit) 09 - string, first byte is length (could it be a byte array?) 0A - string, first byte is length" uansett. 7E <-- Frame Start flag A <-- 4 bits, A = Frame Format Type 3 0E2 <-- 12 bits, Frame size: 0xE2 (226 bytes!?, excluding start/end flags) 2B <-- Destination Address 21 <-- Source Address 13 <-- Control Field 239A <-- Gyldig CRC-16/X-25 E6 <-- Destination LSAP E7 <-- Source LSAP 00 <-- LLC Quality 0F <-- Information, n*8 bits? 0000F8BF60D95 <-- Hva er dette? Ofte(?) likt 09 12 6A58000F0FF682A566B1797AE17AE650582828A4A641428FE 0A 1135372036353627323132343834373536 <-- Gyldig målernummer i ASCII (NB: jeg endret noen sifre her, så evt påfølgende checksum vil feile) 09 06 01017CF1 <-- Hva er dette? Alltid likt 0A 12 36383431313331424E323433313031303430 <-- Alltid likt = ASCII 6841131BN243101040 <-- 684113 = måler-type 09 06 81F9FF 06 80FF96C828FF 06 C0FF 06 E0 06 F089C7FE7408 06 00F897C8287E 09 06 F13AC4 06 00FC4A6414DF10 06 00FCFF 12 C02FC85058FF3BE6 12 00EC <-- 236 (Volt? (L2?)) 09 06 01F1D8 <-- Hva er dette? 12 00EB <-- 235 (Volt? (L3?)) 3DC0 <-- Checksum? 7E <-- Frame End flag Oppsettet for avlesingen er slik jeg hadde forventet det å være: ser = serial.Serial( port='/dev/ttyUSB0', baudrate=2400, parity=serial.PARITY_NONE, stopbits=serial.STOPBITS_ONE, bytesize=serial.EIGHTBITS, timeout=10) Håper noen har noen tips eller innspill til meldingene. ?
  • Medlemsstatistikk

    6 764
    Totalt antall medlemmer
    1 891
    Flest pålogget
    ArtHav
    Nyeste medlem
    ArtHav
    Ble med
×
×
  • Opprett ny...

Viktig informasjon

Vi har plassert informasjonskapsler/cookies på din enhet for å gjøre denne siden bedre. Du kan justere dine innstillinger for informasjonskapsler, ellers vil vi anta at dette er ok for deg.