Gå til innhold
  • Bli medlem

Søk i nettsamfunnet

Viser resultater for emneknaggene 'z-wave'.



Flere søkevalg

  • Søk etter emneknagger

    Skriv inn nøkkelord separert med kommaer.
  • Søk etter forfatter

Innholdstype


Kategorier

  • Generelt
    • Automasjonskaféen
    • Annen Elektronikk
    • Ditt system
    • Grafikk og design
    • Nettverk
    • Nybegynner
  • Bruksområder
    • A/V-kontroll
    • Belysning
    • Klimakontroll
    • Overvåking
    • Sikkerhet
    • Strømsparing
    • Talestyring
  • Systemer
    • Domoticz
    • Fibaro Home Center
    • Futurehome
    • HDL
    • Home Assistant
    • HomeKit
    • HomeSeer
    • Homey
    • Indigo Domotics
    • openHAB
    • Sensio
    • SmartThings
    • Telldus Live!
    • Vera
    • Z-Way
    • Zipato
    • Øvrige systemer
  • Teknologi / Protokoller
    • Blåtann
    • irDA
    • KNX
    • MQTT
    • RF
    • xComfort
    • Z-Wave
    • ZigBee
  • Utlån, kjøp og salg
    • Prisjakt
    • Kjøp / Salg
    • Powerbuy
    • Kommersielle tilbud
    • Utlån
  • Nettstedet
    • Kunngjøringer
    • Nyheter
    • Ris, ros og spørsmål om forumet

Blogger

  • En teknologisk hverdag
  • Enda en hobby?
  • Smånytt
  • en guide til elektro-verdenen

Kategorier

  • Nyheter
    • Produkter
    • Programvare
  • Tester
    • Systemer
  • Guider
    • Fibaro
    • HomeSeer
    • Nettverk
    • openHAB
    • Z-Wave

Finn resultater i...

Finn resultater som...


Startdato

  • Start

    Slutt


Sist oppdatert

  • Start

    Slutt


Filtrer etter antall...

Ble med

  • Start

    Slutt


Gruppe


System

Fant 130 resultater

  1. Jeg tenkte å teste en enkel av/på-mottaker fra Nexa fordi den var billig. Denne fungere ok til nå, men jeg får opp melding om "power has been applied" omtrent hvert 5. minutt. Dette er en helt jevn intervall. Det er ingen fysisk vibrasjon eller påvirkning på selve bryteren. Det er heller ikke koblet til fysisk bryter enda, så den står helt for seg selv. Noen andre som har opplevd et lignende problem? Det har vel ikke nødvendigvis en praktisk betydning, men den kan jo være defekt, eller ha dårlig kontakt. Kan det være en innstilling? Jeg bruker Fibaro HCL. Jeg vet at dimmeren til Nexa ikke fungere særlig bra så misstenker jo at kvaliteten på denne heller ikke er så bra.
  2. Master Aeon

    Temperatursensor til basseng/jacuzzi

    Det ser ikke ut til å eksistere et eget Z-Wave-produkt som måler temperaturen på vannet i basseng eller jauzzi ennå. Så jeg kom over denne oppskriften her som baserer seg på en Fibaro FGK-101 Dør/Vindusensor og en Luxorparts Temperatursensor med kabel (DS18B20) for å måle temperaturen som kobles til Fibaro-sensoren: https://community.home-assistant.io/t/i-made-a-floating-zwave-swimming-pool-temp-probe/24218/5 Nå er denne guiden for Home Assistant, men jeg har Homey. I tillegg så er oppskriften basert på en gammel Fibaro FGK-101 Door Window Sensor. Så vidt jeg kan se så er det bare mulig å kjøpe Fibaro Door Window Sensor 2 som har produktid FGDW-002. Spørsmål 1: Har den nyere Fibaro-sensoren samme mulighet til å koble til temperatursensorkabelen eller finnes det en annen sensor som jeg kan bruke som gjør samme nytten som FGK-101? Spørsmål 2: Homey støtter de fleste Fibaro-enheter, men vil den fange opp data fra temperatursensorkabelen som er koblet til som "ekstrautstyr"?
  3. Jeg har oppgradert min Heatit termostat (med uoriginal kabel for et par kroner, gikk helt fint), men har problem å forstå de nye "kanalene" som dukker opp i openHAB (v. 2.4.0). Jeg får følgende kanaler: Switch switch_binary .. av/på, vet ikke hva den gjør Switch sensor_binary .. vet ikke hva det er; verdiene er oppgitt som "Triggered"/"Untriggered", men jeg ser alltid bare Triggered Switch thermostat_mode .. velge modus: av/på/eco/cool (hvor det siste ikke gjør noe) Number thermostat_setpoint_heating .. setpoint i vanlig modus, funker som forventet Number thermostat_setpoint_cooling .. setpoint i "cooling" modus - ikke i bruk Number thermostat_setpoint_furnace .. vet ikke hva det er, ser ikke å ha noe effekt Number config_decimal_param12 .. styrke i "Power" modus - bruker ikke denne Switch switch_binary1 .. indikator om varmen er på - funker Number sensor_temperature2 .. lufttemperatur, målt inni termostaten .. ganske nytteløst Number sensor_temperature3 .. temperatur fra ekstra sensor .. har ikke Number sensor_temperature4 .. gulvtemperatur (fra føler) .. funker ok Det jeg lurer mest på er: Hva er de første to brytere? Og er de ment som read-only, eller også for styring? Jeg ser at når jeg slår termostaten på manuelt (ved å bruker kanal 8, dvs. rele-switch), så skifter kanal 1 fra 'av' til 'på' - betyr det at dette er en indikator på om termostaten styrer selv, eller bare lar seg styre? (Man må jo nesten ha noe slikt, fordi ellers vill den bare overstyrt den man har gjort?) Hva er kanal 6, dvs setpoint for "furnace"? Er det virkelig ikke mulig å se eller styre setpoint i eco-modus? Det ser jo å gå i HomeSeer, ifølge dette innlegget. Men "device overview" fra Z-wave databasen sier at eko-modus skiller seg bare med større hysterese - noe som høres merkelig ut, siden selve termostaten har klart setpoint for både vanlig/"komfort" og "eko". Forresten vises "ECO mode setpoint" som parameter 11 under konfigurasjon, men denne er ikke synkronisert i termostaten - akkurat som de andre parametrene der - er det vanlig? Forresten har jeg satt alle 5 "association groups" i konfigurasjonen til "Controller".
  4. Holder på med totalrenovering og påbygg av enebolig fra 1975, og skal i den forbindelse slenge meg på bølgen med sentralstyrt "alt". Foreløpig vil jeg egentlig ikke kalle det for automasjon, da ingenting er automagisk ennå, og boligen fortsatt er under renovering/oppføring. Det er likevel blitt tatt ett viktig valg, og det er å bruke LogicMachine som hjerne i systemet, kombinert med en server som alle data skal mates inn i på sikt. Jeg er systemutvikler av yrke, så jeg liker at det meste kan hackes på. Lys skal for det meste styres via DALI, og det som ikke går på DALI skal styres via KNX. For interface til brukere vil det mest sannsynlig anskaffes veggmonterte 10" tablets som kjører Android og er matet via PoE. Når det gjelder sensordata er det ekstremt mye å velge imellom, og her har jeg noen idéer. Til enkle sensorer, som temperatur som skal støpes ned, faller sikkert valget på 1-wire, da jeg spesifikt har sett på DS18B20. For alle rom hadde det vært interessant å ha røkvarslere, gjerne kombinert med temperatur, co2, bevegelse, lys, og fuktighet, men så langt har jeg ennå ikke funnet noen jeg synes ser lovende ut (og til en ok pris). EDIT: Skal også ha vannbåren varme i hele huset, og i tillegg elektriske varmekabler på bad (har blitt anbefalt som en slags backup). Dette skal også styres via hele systemet og baseres på sensordata. Skal på sikt få lagt ut litt plantegninger med hva som er tenkt av sensor, lys og kontrollpanel. Det må bare lages først Som en teaser kan jeg legge ut blanke plantegninger.
  5. Reidar Gjertsen

    Hvilken Z-Wave controller bør jeg velge?

    Hei, Jeg er veldig ny til hjemmeautomasjon ennå, men har veldig stor interesse for det! Planen var å begynne litt i det små med noen Fibaro Wall Plugs og litt Philips Hue lys. Jeg synes Fibaro sin Home Center app ser veldig gammeldags og kjedelig ut, men har ikke sett på så mange andre. Da jeg googlet litt kom jeg frem til Fibaro, Homey og HomeSeer. Jeg antar at alle disse kan styre alt fra Fibaro og Philips Hue, men har dere noen tanker om hvilken som er enklest og mest brukervennlig app? Tar i mot alle tips jeg kan få
  6. Hei! I sikringsskapet har vi en mekanisk måler som måler forbruket til hybelen i tillegg til hovedhuset sin AMS måler. Jeg har hørt at disse eldre mekaniske målerne går opp til 10% feil og ønsker å bytte ut denne med noe digitalt. Elektriker gjør dette, men jeg ønsker å kjøpe inn måleren i forkant. Jeg er usikker på om spesifikasjonene er riktig og hva jeg trenger. Dette er informasjon på AMS måleren min. 1. Kan denne i fra Qubino brukes hos meg? Type (tilkobling): enfase (1b) Referanse strøm (iref): 5 A Maks strøm (Imax): 65 A Minimum strøm (Imin): 0.25 A Startstrøm : 20 mA Spenning (Un): 230 V (± 20%) Strømforbruk ved Un: <2W Nominell frekvens (fn): 50 og 60 Hz https://www.eldirekte.no/qubino-smart-energimaler-z-wave/cat-p/c/p10637337?gclid=Cj0KCQiArenfBRCoARIsAFc1FqeQUr3vk510C0pF8yWbPP2vo7FKz9VDGPv-f2Th5JwwHhG4BnKGNqwaAgKQEALw_wcB 2. Eventuelt denne: https://www.elektroimportoren.no/qubino-smart-meter-energimaaler-z-wave/4512304/Product.html?Event=livesearch 3. Så er jeg ganske ny når det gjelder smarthus og feil kan fort skje med serveren/homeseer slik at jeg kan trenge en fullstendig resett av systemet. Er det noen som vet om informasjon om strømforbruk lagres på z-wave enheten slik at jeg får lest ut forbruket på hybelen når systemet er oppe å gå igjen? Takk for svar!
  7. Hei! Jeg er helt fersk og nettopp kjøpt HomeTroller Zee S2 med Z-Wave Plus USB (euro). Tenkte jeg skulle begynne å legg til Z-wave devices, men da jeg gikk inn på Plugins -> Z-Wave -> Controller Management, fikk jeg ikke valgt Interface Actions (finnes ingen alternativer jeg kan velge). Jeg ser et gult ikon med utropstegn som gir meg feilmeldingen: "Trouble. The interface is experiencing trouble initializing. Click to take this interface/controller OFFLINE (It will not be usable)". Noen som vet hva som foregår?:)
  8. Norumen

    Automatisere lys av/på vha. Z-wave

    Hei. Jeg er helt ny på hjemmeautomasjonsfronten. Akkurat kjøpt Vera Plus og ett sett med motor og bryter for å automatisere rullegardina på soverommet. Enda ikke satt opp dette, skal prøve på det i helga. Gleder meg som en liten unge, dama begynner å bli lei av at jeg prater om alt jeg skal automatisere hele tiden😂 Hun ser heldigvis fordelene av automatisering så det er bra. Håper ikke spørsmålene under blir for dumme, prøvd å google rundt etter svar, men vanskelig å finne ut av ting med tesje. Jobber teknisk innen IT, så litt Med en gang jeg begynte å se på hjemmeautomasjon så fikk jeg lyst til å automatisere "hele" huset. Ønsker å starte med å kunne slå av/på lyst på visse rom basert på begevelse og lys og tidsstyring. Ser at Fibaro har en multisensor til rundt 500 kroner. Er denne bra for dette formålet? Noen steder trenger jeg ikke lyssensor (lux), finnes det da billigere sensorer (kanskje 433 mhz)? Er dette bra nok? Så ser jeg på hva jeg må ha som bryter. Ser at fibaro har ett "relee" som jeg tror det kalles som man putter inne i bryteren for å kunne både bruke bryteren og regler via Z-wave. Ser også at det finnes "hele" brytere med innebygd Z-wave funksjonalitet der man bytter ut den orginale bryteren. Hva anbefales her? Bytte ut hele eller putte inn ett relee? Finnes det merker som er bra og merker jeg bør holde meg unna?
  9. Hei, dette er mitt første innlegg. Er helt fersk på hjemmeautomasjon, men har i hvert fall begynt å sette opp HomeAssistant. Har bakgrunn fra kontrollsystemer i jobb, så er ikke helt grønn på grunnprinsipper. Vi skal pusse opp på nyåret, og skal ha 4 nye soner med varmegulv (2 soverom med folie, en gang med kabler og et lite do-rom med kabler). Det var dette som trigget hjemmeautomasjonsløsning for meg, siden jeg kunne tenke meg å kunne sette opp en intelligent varmestyring, samt ha fjernstyring for de gangene vi ikke er hjemme. Der poppet HeatIt/Multireg (thermo-florr) sin termostat opp som et alternativ. Når jeg går inn på deres hjemmesider, så står det noe om at Z-therm2 skal komme for å ta over for første generasjon. Spurte hva hovedforskjellene er, og fikk dette som svar: - OTA (over -the-air oppdatering). (det går vel å oppdatere med kabel nå(?!)) - strømmåling (ikke kritisk) - Mulitlevel sensor (kan avlese temperatur til alle tilkoblede følere) (er dette nyttig? blir kun regulering av gulvtemp på det ene gulvet) - S2 sikkerhet (kryptert) (går dette sammen med Home Assistant?) - relestatus (ser inn/ut status i gateway'n) (Kan være lurt) Den nye kommer ikke før på nyåret, så vil sannsynligvis være klar til vi får gjort gulvvarmejobben, siden det er en prosess med omfiksing av gulv etc. Grunnen til at jeg spør er at det er dagstilbud på nåværende modell hos Elektroimportøren på torsdag, der de selges til 999,- Det har jo litt å si, siden jeg skal ha 5 (4 nye gulv + eksisterende bad), så har jo da 2000 å spare... Håper å poste litt mer i forumet her i løpet av vinteren når ting skal sys ferdig -Kristian
  10. Jeg har lurt litt på hvordan jeg kan bruke RGB-lys og en MiCube fra Xiaomi (lett integrerbart i HomeSeer med deCONZ/JowiHue). Har laget et par scripts til det. Se bloggen for en video. Det første justerer lysstyrken med å vri på kuben. Hvilket farge (eller lys) den styrer er avhengig av hvilken side som vender opp. Settes opp slik: ... og i eksempelet over er 2566 er rotasjon-devicen, 2565 er side-devicen. 900, 901 og 902 er devicer for hhv. rød, grønn og blå. Den oppmerksomme leser vil legge merke til at det er mulig å styre flere lys samtidig (greenID1+greenID2+....). F.eks. ville 990+1045+1077 styre tre forskjellige lys. Praktisk hvis man har flere RGB-lenker i samme rom. Jeg bruker den muligheten i stua. MiCube_RGB.vb Du trenger selvfølgelig ikke bruke rød, grønn og blå, du kan bruke andre devicer så lenge de bruker vanlige 0-99-nivåer. Med en liten endring kan du styre opp til 6 forskjellige lys fra en kube. Det andre scriptet skal skru av og på med et "dobbelt tap", men kan også brukes til å styre noe når siden flippes over. Her trengs kun side-rotasjonen, men har et ekstra tillegg for å skru av alle lys. Device 989 er "all colors" på en Fibaro RGBW modul. MiCube_side.vb
  11. Jeg har en "The Button" fra Fibaro som har fungert fint i en måneds tid, men som plutselig bare har sluttet å fungere. Når jeg fjernet den fra Z-Wave nettverket til Homey så reagerte den på at jeg trykket 4 ganger på The Button og fjernet den. Jeg la den til igjen og det fungerte like fint. Jeg oppdaterte så mine 3 flows med "ny" button for 1, 2 og 3 trykk på knappen og prøvde igjen. Fremdeles intet som skjer i Homey. Kjører jeg de aktuelle flows via Test i Homey PC softwaren så fungerer det fint. Jeg prøvde derfor å logge hva som skjer via developer.athom.com så jeg slo på logging under Z-Wave. Deretter gjorde jeg følgende - som faktisk ble logget av Homey, dvs. Homey ser når jeg trykker på The Button, men gidder ikke kjøre de aktuelle flows (som tidligere fungerte fint): - Først 4 trykk for å "vekke opp" knappen ifølge manualen (Node 38 er Fibaro Button): [2018-12-01T14:46:07.689Z] Node[38]: Received application command for COMMAND_CLASS_SECURITY, data: 0x40 [2018-12-01T14:46:07.693Z] Node[38]: [COMMAND_CLASS_SECURITY] {} [2018-12-01T14:46:07.694Z] Node[38]: [COMMAND_CLASS_SECURITY] [SECURITY_NONCE_REPORT] {"type":"Buffer","data":[97,247,56,238,79,130,208,255]} [2018-12-01T14:46:07.694Z] Node[38]: sendData to COMMAND_CLASS_SECURITY, params 0x8061f738ee4f82d0ff [2018-12-01T14:46:07.699Z] Command[222] start: sendData [2018-12-01T14:46:07.711Z] ProcessSendData[208]: To node: 38 with data: 0x988061f738ee4f82d0ff and txOptions: AUTO_ROUTE,EXPLORE [2018-12-01T14:46:07.736Z] Command[222] end: sendData [2018-12-01T14:46:07.754Z] Node[38]: Received application command for COMMAND_CLASS_SECURITY, data: 0x81da3aa0ac10c3d44024bd18f7aa26612c7863f5cb3f12ea [2018-12-01T14:46:07.755Z] Node[38]: [COMMAND_CLASS_SECURITY] {"Initialization Vector byte":{"type":"Buffer","data":[218,58,160,172,16,195,212,64]},"Properties1 (Raw)":{"type":"Buffer","data":[36]},"Properties1":{"Sequence Counter":4,"Sequenced":false,"Second Frame":true},"Command byte":{"type":"Buffer","data":[189,24,247,170,38]},"Receivers nonce Identifier (Raw)":{"type":"Buffer","data":[97]},"Receivers nonce Identifier":97,"Message Authentication Code byte":{"type":"Buffer","data":[44,120,99,245,203,63,18,234]}} [2018-12-01T14:46:07.778Z] Node[38]: [COMMAND_CLASS_CENTRAL_SCENE] {"Sequence Number (Raw)":{"type":"Buffer","data":[11]},"Sequence Number":11,"Properties1 (Raw)":{"type":"Buffer","data":[133]},"Properties1":{"Slow Refresh":true,"Key Attributes":"Key Pressed 4 times"},"Scene Number (Raw)":{"type":"Buffer","data":[1]},"Scene Number":1} [2018-12-01T14:46:07.779Z] Node[38]: Decapsulated frame from COMMAND_CLASS_SECURITY to COMMAND_CLASS_CENTRAL_SCENE, data 0x030b8501 - Så ett trykk: [2018-12-01T14:46:29.064Z] Node[38]: Received application command for COMMAND_CLASS_SECURITY, data: 0x40 [2018-12-01T14:46:29.064Z] Node[38]: [COMMAND_CLASS_SECURITY] {} [2018-12-01T14:46:29.064Z] Node[38]: [COMMAND_CLASS_SECURITY] [SECURITY_NONCE_REPORT] {"type":"Buffer","data":[98,0,55,152,189,7,204,171]} [2018-12-01T14:46:29.065Z] Node[38]: sendData to COMMAND_CLASS_SECURITY, params 0x8062003798bd07ccab [2018-12-01T14:46:29.069Z] Command[223] start: sendData [2018-12-01T14:46:29.070Z] ProcessSendData[209]: To node: 38 with data: 0x988062003798bd07ccab and txOptions: AUTO_ROUTE,EXPLORE [2018-12-01T14:46:29.093Z] Command[223] end: sendData [2018-12-01T14:46:29.115Z] Node[38]: Received application command for COMMAND_CLASS_SECURITY, data: 0x81864515042973ccc3c1005ab9752d62bb4a1bd015f8fafa [2018-12-01T14:46:29.116Z] Node[38]: [COMMAND_CLASS_SECURITY] {"Initialization Vector byte":{"type":"Buffer","data":[134,69,21,4,41,115,204,195]},"Properties1 (Raw)":{"type":"Buffer","data":[193]},"Properties1":{"Sequence Counter":1,"Sequenced":false,"Second Frame":false},"Command byte":{"type":"Buffer","data":[0,90,185,117,45]},"Receivers nonce Identifier (Raw)":{"type":"Buffer","data":[98]},"Receivers nonce Identifier":98,"Message Authentication Code byte":{"type":"Buffer","data":[187,74,27,208,21,248,250,250]}} [2018-12-01T14:46:29.129Z] Node[38]: [COMMAND_CLASS_CENTRAL_SCENE] {"Sequence Number (Raw)":{"type":"Buffer","data":[12]},"Sequence Number":12,"Properties1 (Raw)":{"type":"Buffer","data":[128]},"Properties1":{"Slow Refresh":true,"Key Attributes":"Key Pressed 1 time"},"Scene Number (Raw)":{"type":"Buffer","data":[1]},"Scene Number":1} [2018-12-01T14:46:29.129Z] Node[38]: Decapsulated frame from COMMAND_CLASS_SECURITY to COMMAND_CLASS_CENTRAL_SCENE, data 0x030c8001 - Så 2 trykk for en annen flow: [2018-12-01T14:46:56.558Z] Node[38]: Received application command for COMMAND_CLASS_SECURITY, data: 0x40 [2018-12-01T14:46:56.559Z] Node[38]: [COMMAND_CLASS_SECURITY] {} [2018-12-01T14:46:56.559Z] Node[38]: [COMMAND_CLASS_SECURITY] [SECURITY_NONCE_REPORT] {"type":"Buffer","data":[99,212,171,197,27,76,90,24]} [2018-12-01T14:46:56.559Z] Node[38]: sendData to COMMAND_CLASS_SECURITY, params 0x8063d4abc51b4c5a18 [2018-12-01T14:46:56.567Z] Command[224] start: sendData [2018-12-01T14:46:56.567Z] ProcessSendData[210]: To node: 38 with data: 0x988063d4abc51b4c5a18 and txOptions: AUTO_ROUTE,EXPLORE [2018-12-01T14:46:56.586Z] Command[224] end: sendData [2018-12-01T14:46:56.610Z] Node[38]: Received application command for COMMAND_CLASS_SECURITY, data: 0x818d5b5ae6a77fce77433c78fba64e63415392dc711df0b6 [2018-12-01T14:46:56.611Z] Node[38]: [COMMAND_CLASS_SECURITY] {"Initialization Vector byte":{"type":"Buffer","data":[141,91,90,230,167,127,206,119]},"Properties1 (Raw)":{"type":"Buffer","data":[67]},"Properties1":{"Sequence Counter":3,"Sequenced":false,"Second Frame":false},"Command byte":{"type":"Buffer","data":[60,120,251,166,78]},"Receivers nonce Identifier (Raw)":{"type":"Buffer","data":[99]},"Receivers nonce Identifier":99,"Message Authentication Code byte":{"type":"Buffer","data":[65,83,146,220,113,29,240,182]}} [2018-12-01T14:46:56.626Z] Node[38]: [COMMAND_CLASS_CENTRAL_SCENE] {"Sequence Number (Raw)":{"type":"Buffer","data":[13]},"Sequence Number":13,"Properties1 (Raw)":{"type":"Buffer","data":[131]},"Properties1":{"Slow Refresh":true,"Key Attributes":"Key Pressed 2 times"},"Scene Number (Raw)":{"type":"Buffer","data":[1]},"Scene Number":1} [2018-12-01T14:46:56.627Z] Node[38]: Decapsulated frame from COMMAND_CLASS_SECURITY to COMMAND_CLASS_CENTRAL_SCENE, data 0x030d8301 - Så 3 trykk. Homey kjører ingen flows på noen av de: [2018-12-01T14:47:16.401Z] Node[38]: Received application command for COMMAND_CLASS_SECURITY, data: 0x40 [2018-12-01T14:47:16.401Z] Node[38]: [COMMAND_CLASS_SECURITY] {} [2018-12-01T14:47:16.402Z] Node[38]: [COMMAND_CLASS_SECURITY] [SECURITY_NONCE_REPORT] {"type":"Buffer","data":[100,218,214,175,94,133,193,248]} [2018-12-01T14:47:16.402Z] Node[38]: sendData to COMMAND_CLASS_SECURITY, params 0x8064dad6af5e85c1f8 [2018-12-01T14:47:16.407Z] Command[225] start: sendData [2018-12-01T14:47:16.407Z] ProcessSendData[211]: To node: 38 with data: 0x988064dad6af5e85c1f8 and txOptions: AUTO_ROUTE,EXPLORE [2018-12-01T14:47:16.426Z] Command[225] end: sendData [2018-12-01T14:47:16.450Z] Node[38]: Received application command for COMMAND_CLASS_SECURITY, data: 0x818b838cbbfd0c3591f5c649054f2d641469c0c52ea9648b [2018-12-01T14:47:16.451Z] Node[38]: [COMMAND_CLASS_SECURITY] {"Initialization Vector byte":{"type":"Buffer","data":[139,131,140,187,253,12,53,145]},"Properties1 (Raw)":{"type":"Buffer","data":[245]},"Properties1":{"Sequence Counter":5,"Sequenced":true,"Second Frame":true},"Command byte":{"type":"Buffer","data":[198,73,5,79,45]},"Receivers nonce Identifier (Raw)":{"type":"Buffer","data":[100]},"Receivers nonce Identifier":100,"Message Authentication Code byte":{"type":"Buffer","data":[20,105,192,197,46,169,100,139]}} [2018-12-01T14:47:16.470Z] Node[38]: [COMMAND_CLASS_CENTRAL_SCENE] {"Sequence Number (Raw)":{"type":"Buffer","data":[14]},"Sequence Number":14,"Properties1 (Raw)":{"type":"Buffer","data":[132]},"Properties1":{"Slow Refresh":true,"Key Attributes":"Key Pressed 3 times"},"Scene Number (Raw)":{"type":"Buffer","data":[1]},"Scene Number":1} [2018-12-01T14:47:16.471Z] Node[38]: Decapsulated frame from COMMAND_CLASS_SECURITY to COMMAND_CLASS_CENTRAL_SCENE, data 0x030e8401 - Deretter en vellykket av-knapp på NodOn wall switch til slutt, dvs. flow ble kjørt via NodOn-switchen (Node 3): [2018-12-01T14:49:55.910Z] Node[3]: Received application command for COMMAND_CLASS_CENTRAL_SCENE, data: 0x03e10003 [2018-12-01T14:49:55.911Z] Node[3]: [COMMAND_CLASS_CENTRAL_SCENE] {"Sequence Number (Raw)":{"type":"Buffer","data":[225]},"Sequence Number":225,"Properties1 (Raw)":{"type":"Buffer","data":[0]},"Properties1":{"Key Attributes":"Key Pressed 1 time"},"Scene Number (Raw)":{"type":"Buffer","data":[3]},"Scene Number":3} [2018-12-01T14:49:56.001Z] Node[3]: Received application command for COMMAND_CLASS_WAKE_UP, data: 0x07 [2018-12-01T14:49:56.001Z] Node[3]: [COMMAND_CLASS_WAKE_UP] {} [2018-12-01T14:49:56.003Z] Node[3]: Marked as online [2018-12-01T14:49:56.074Z] Node[3]: [COMMAND_CLASS_BATTERY] [BATTERY_GET] {"type":"Buffer","data":[]} [2018-12-01T14:49:56.075Z] Node[3]: sendData to COMMAND_CLASS_BATTERY, params 0x02 [2018-12-01T14:49:56.076Z] Command[226] start: sendData [2018-12-01T14:49:56.076Z] ProcessSendData[212]: To node: 3 with data: 0x8002 and txOptions: AUTO_ROUTE,ACK,EXPLORE [2018-12-01T14:49:56.122Z] Node[9]: [COMMAND_CLASS_SWITCH_MULTILEVEL] [SWITCH_MULTILEVEL_SET] {"type":"Buffer","data":[0]} [2018-12-01T14:49:56.123Z] Node[9]: sendData to COMMAND_CLASS_SWITCH_MULTILEVEL, params 0x0100 [2018-12-01T14:49:56.126Z] Node[6]: [COMMAND_CLASS_SWITCH_MULTILEVEL] [SWITCH_MULTILEVEL_SET] {"type":"Buffer","data":[0]} [2018-12-01T14:49:56.127Z] Node[6]: sendData to COMMAND_CLASS_SWITCH_MULTILEVEL, params 0x0100 [2018-12-01T14:49:56.136Z] Node[8]: [COMMAND_CLASS_SWITCH_MULTILEVEL] [SWITCH_MULTILEVEL_SET] {"type":"Buffer","data":[0]} [2018-12-01T14:49:56.136Z] Node[8]: sendData to COMMAND_CLASS_SWITCH_MULTILEVEL, params 0x0100 [2018-12-01T14:49:56.143Z] Node[36]: [COMMAND_CLASS_SWITCH_BINARY] [SWITCH_BINARY_SET] {"type":"Buffer","data":[0]} [2018-12-01T14:49:56.143Z] Node[36]: sendData to COMMAND_CLASS_SWITCH_BINARY, params 0x0100 [2018-12-01T14:49:56.144Z] Command[226] end: sendData [2018-12-01T14:49:56.144Z] Command[227] start: sendData [2018-12-01T14:49:56.145Z] ProcessSendData[213]: To node: 9 with data: 0x260100 and txOptions: AUTO_ROUTE,ACK,EXPLORE [2018-12-01T14:49:56.151Z] Node[37]: [COMMAND_CLASS_SWITCH_BINARY] [SWITCH_BINARY_SET] {"type":"Buffer","data":[0]} [2018-12-01T14:49:56.151Z] Node[37]: sendData to COMMAND_CLASS_SWITCH_BINARY, params 0x0100 [2018-12-01T14:49:56.172Z] Command[227] end: sendData [2018-12-01T14:49:56.173Z] Command[228] start: sendData [2018-12-01T14:49:56.173Z] ProcessSendData[214]: To node: 6 with data: 0x260100 and txOptions: AUTO_ROUTE,ACK,EXPLORE [2018-12-01T14:49:56.243Z] Node[3]: Received application command for COMMAND_CLASS_BATTERY, data: 0x034c [2018-12-01T14:49:56.244Z] Node[3]: [COMMAND_CLASS_BATTERY] {"Battery Level (Raw)":{"type":"Buffer","data":[76]},"Battery Level":{}} [2018-12-01T14:49:56.285Z] Node[3]: Received application command for COMMAND_CLASS_BATTERY, data: 0x034c [2018-12-01T14:49:56.286Z] Node[3]: [COMMAND_CLASS_BATTERY] {"Battery Level (Raw)":{"type":"Buffer","data":[76]},"Battery Level":{}} [2018-12-01T14:49:56.303Z] Command[228] end: sendData [2018-12-01T14:49:56.304Z] Command[229] start: sendData [2018-12-01T14:49:56.304Z] ProcessSendData[215]: To node: 8 with data: 0x260100 and txOptions: AUTO_ROUTE,ACK,EXPLORE [2018-12-01T14:49:56.340Z] Node[3]: Received application command for COMMAND_CLASS_CENTRAL_SCENE, data: 0x03e10003 [2018-12-01T14:49:56.343Z] Node[3]: [COMMAND_CLASS_CENTRAL_SCENE] {"Sequence Number (Raw)":{"type":"Buffer","data":[225]},"Sequence Number":225,"Properties1 (Raw)":{"type":"Buffer","data":[0]},"Properties1":{"Key Attributes":"Key Pressed 1 time"},"Scene Number (Raw)":{"type":"Buffer","data":[3]},"Scene Number":3} [2018-12-01T14:49:56.532Z] Node[3]: Received application command for COMMAND_CLASS_CENTRAL_SCENE, data: 0x03e10003 [2018-12-01T14:49:56.533Z] Node[3]: [COMMAND_CLASS_CENTRAL_SCENE] {"Sequence Number (Raw)":{"type":"Buffer","data":[225]},"Sequence Number":225,"Properties1 (Raw)":{"type":"Buffer","data":[0]},"Properties1":{"Key Attributes":"Key Pressed 1 time"},"Scene Number (Raw)":{"type":"Buffer","data":[3]},"Scene Number":3} [2018-12-01T14:49:56.575Z] Node[3]: Received application command for COMMAND_CLASS_CENTRAL_SCENE, data: 0x03e10003 [2018-12-01T14:49:56.575Z] Node[3]: [COMMAND_CLASS_CENTRAL_SCENE] {"Sequence Number (Raw)":{"type":"Buffer","data":[225]},"Sequence Number":225,"Properties1 (Raw)":{"type":"Buffer","data":[0]},"Properties1":{"Key Attributes":"Key Pressed 1 time"},"Scene Number (Raw)":{"type":"Buffer","data":[3]},"Scene Number":3} [2018-12-01T14:49:56.611Z] Command[229] end: sendData [2018-12-01T14:49:56.611Z] Command[230] start: sendData [2018-12-01T14:49:56.612Z] ProcessSendData[216]: To node: 36 with data: 0x250100 and txOptions: AUTO_ROUTE,ACK,EXPLORE [2018-12-01T14:49:56.720Z] Command[230] end: sendData [2018-12-01T14:49:56.721Z] Command[231] start: sendData [2018-12-01T14:49:56.721Z] ProcessSendData[217]: To node: 37 with data: 0x250100 and txOptions: AUTO_ROUTE,ACK,EXPLORE [2018-12-01T14:49:56.789Z] Node[36]: Received application command for COMMAND_CLASS_SWITCH_BINARY, data: 0x0300 [2018-12-01T14:49:56.789Z] Node[36]: [COMMAND_CLASS_SWITCH_BINARY] {"Value (Raw)":{"type":"Buffer","data":[0]},"Value":"off/disable"} [2018-12-01T14:49:56.832Z] Command[231] end: sendData [2018-12-01T14:49:56.857Z] Node[37]: Received application command for COMMAND_CLASS_SWITCH_BINARY, data: 0x0300 [2018-12-01T14:49:56.857Z] Node[37]: [COMMAND_CLASS_SWITCH_BINARY] {"Value (Raw)":{"type":"Buffer","data":[0]},"Value":"off/disable"} [2018-12-01T14:49:59.506Z] Node[3]: [COMMAND_CLASS_WAKE_UP] [WAKE_UP_NO_MORE_INFORMATION] {"type":"Buffer","data":[]} [2018-12-01T14:49:59.506Z] Node[3]: sendData to COMMAND_CLASS_WAKE_UP, params 0x08 [2018-12-01T14:49:59.511Z] Command[232] start: sendData [2018-12-01T14:49:59.512Z] ProcessSendData[218]: To node: 3 with data: 0x8408 and txOptions: AUTO_ROUTE,ACK,EXPLORE [2018-12-01T14:49:59.571Z] Node[36]: Received application command for COMMAND_CLASS_METER, data: 0x0221140000000b01f70000001200 [2018-12-01T14:49:59.574Z] Node[36]: [COMMAND_CLASS_METER] {"Properties1 (Raw)":{"type":"Buffer","data":[33]},"Properties1":{"Scale bit 2":false,"Meter Type":"Electric meter","Rate Type":"Import","Meter Type (Parsed)":{"value":"Electric meter"},"Rate Type (Parsed)":{"value":"Import"}},"Properties2 (Raw)":{"type":"Buffer","data":[20]},"Properties2":{"Size":4,"Scale bits 10":2,"Precision":0},"Meter Value":{"type":"Buffer","data":[0,0,0,11]},"Delta Time (Raw)":{"type":"Buffer","data":[1,247]},"Delta Time":503,"Previous Meter Value":{"type":"Buffer","data":[0,0,0,18]},"Scale 2 (Raw)":{"type":"Buffer","data":[0]},"Scale 2":0,"Meter Value (Parsed)":11,"Previous Meter Value (Parsed)":18} [2018-12-01T14:49:59.674Z] Node[36]: Received application command for COMMAND_CLASS_METER, data: 0x0221140000000b01f70000001200 [2018-12-01T14:49:59.675Z] Node[36]: [COMMAND_CLASS_METER] {"Properties1 (Raw)":{"type":"Buffer","data":[33]},"Properties1":{"Scale bit 2":false,"Meter Type":"Electric meter","Rate Type":"Import","Meter Type (Parsed)":{"value":"Electric meter"},"Rate Type (Parsed)":{"value":"Import"}},"Properties2 (Raw)":{"type":"Buffer","data":[20]},"Properties2":{"Size":4,"Scale bits 10":2,"Precision":0},"Meter Value":{"type":"Buffer","data":[0,0,0,11]},"Delta Time (Raw)":{"type":"Buffer","data":[1,247]},"Delta Time":503,"Previous Meter Value":{"type":"Buffer","data":[0,0,0,18]},"Scale 2 (Raw)":{"type":"Buffer","data":[0]},"Scale 2":0,"Meter Value (Parsed)":11,"Previous Meter Value (Parsed)":18} [2018-12-01T14:49:59.728Z] Node[37]: Received application command for COMMAND_CLASS_METER, data: 0x0221140000000d01f50000001400 [2018-12-01T14:49:59.730Z] Node[37]: [COMMAND_CLASS_METER] {"Properties1 (Raw)":{"type":"Buffer","data":[33]},"Properties1":{"Scale bit 2":false,"Meter Type":"Electric meter","Rate Type":"Import","Meter Type (Parsed)":{"value":"Electric meter"},"Rate Type (Parsed)":{"value":"Import"}},"Properties2 (Raw)":{"type":"Buffer","data":[20]},"Properties2":{"Size":4,"Scale bits 10":2,"Precision":0},"Meter Value":{"type":"Buffer","data":[0,0,0,13]},"Delta Time (Raw)":{"type":"Buffer","data":[1,245]},"Delta Time":501,"Previous Meter Value":{"type":"Buffer","data":[0,0,0,20]},"Scale 2 (Raw)":{"type":"Buffer","data":[0]},"Scale 2":0,"Meter Value (Parsed)":13,"Previous Meter Value (Parsed)":20} [2018-12-01T14:49:59.785Z] Node[37]: Received application command for COMMAND_CLASS_METER, data: 0x0221140000000d01f50000001400 [2018-12-01T14:49:59.786Z] Node[37]: [COMMAND_CLASS_METER] {"Properties1 (Raw)":{"type":"Buffer","data":[33]},"Properties1":{"Scale bit 2":false,"Meter Type":"Electric meter","Rate Type":"Import","Meter Type (Parsed)":{"value":"Electric meter"},"Rate Type (Parsed)":{"value":"Import"}},"Properties2 (Raw)":{"type":"Buffer","data":[20]},"Properties2":{"Size":4,"Scale bits 10":2,"Precision":0},"Meter Value":{"type":"Buffer","data":[0,0,0,13]},"Delta Time (Raw)":{"type":"Buffer","data":[1,245]},"Delta Time":501,"Previous Meter Value":{"type":"Buffer","data":[0,0,0,20]},"Scale 2 (Raw)":{"type":"Buffer","data":[0]},"Scale 2":0,"Meter Value (Parsed)":13,"Previous Meter Value (Parsed)":20} [2018-12-01T14:50:00.051Z] Command[232] end: sendData [2018-12-01T14:50:00.052Z] Node[3]: Marked as offline Hva skal man se etter i disse loggene? Jeg har ingen erfaring på å trace disse loggene så om noen kan peke ut hva jeg skal se etter så setter jeg stor pris på det. Eksempelvis kommer det frem et sted i loggen at den ikke greier å kjøre en flow? Ser man i den siste loggen for veggbryteren NodOn at alt gikk ok for sammenligningens skyld?
  12. henningl

    Z-wave : no more info feilmelding

    Får jevnlig vedlagte feilmelding i Homeseer-loggen og klarer ikke finne ut av hva det skyldes. Det skjer bare enkelte batteri-enheter, og det ser ut til at når feilen skjer får jeg ikke oppdatert verdi fra enheten. Har prøvd å redusere polling av batteri-enheter til et minimum, men det er et par som behøver det, kanskje mest frustrerende er at feilen av og til skjer på NorthQ-måleren som teller blink på strømmåleren. Når jeg ikke får jevnlig verdi derfra går det litt i ball for scriptene mine som beregner gjennomsnittlig strømforbruk siste 5-15-30-45-60 minutter. Det virker også som om feilen kommer og går. Enkelte dager kan det være mye, andre dager ingenting. Noen tips
  13. Har: ID Lock 150 med Z-Wave modul og HomeSeer Ønsker: Lys for å vise på utsiden om dør er låst eller ikke Bakgrunn: Låsen settes til å være åpen og låst på forskjellige tidspunkt ved å sette parameter 1 og 5. Problemet er om noen legger hånda på låsen for å aktivere touch-panelet fordi de tror at døra er låst, da låses døra! For å unngå dette ønsker jeg å ha et grønt lys som viser om låsen er ulåst og rødt lys som viser at døra er låst. Jeg har forsøkt å lese meg opp på forskjellige mulige løsninger og har kommet til at en Fibaro RGBW kontroller og LED stripe bør kunne fungere. Denne kan vel enkelt settes til å lyse grønt og rødt og også f.eks blinke rødt om noen taster feil kode. Når det gjelder LED striper har jeg ikke noen erfaring i det hele tatt, men trenger da ikke noen lang 5 meter. Kan denne fra Komplett brukes? Tar gjerne i mot tips hvilken type og hvor man kan kjøpe kontroller som vil fungere også.
  14. Noen som vet om det finnes trådløse dimmere ala Fibaro for to-pols bryting av strøm til bad? Dette er jo et krav i våtrom på 230V såvidt jeg klarer å lese.
  15. TL:DR - https://shop.homeseer.com har startet Black Friday - 50% på software bla. Hei, jeg er veldig i startgropen på HA og har lest litt rundt angående kontrollere som er aktuelle for meg. En liten stund tenkte jeg Smartthings3 men så fant jeg Vera\Wink .. og nå for et par dager siden har jeg lest litt om Homeseer. Det at Homeseer kan kjøres på egen maskinvare er stort pluss. Fant frem siden til Homeseer i dag og joda, de har begynt Black Friday salget allerede.. 50% av på programvaren. Tenker jeg går for HS3Pro. Ikke at jeg trenger det men da vet jeg at det ikke kommer ekstrakostnader på akkurat den biten (fant ut at plugins og slikt fort koster litt ekstra). Hvilken Zwave stikke bør jeg bruke? Tenker Aeotec Z-Stick Gen 5 Z-Wave må være grei? Eller er det fordeler\ulemper ved denne vs andre? Ser de selger den på komplett. Vil tro mesteparten av duppeditter jeg kjøper går på zwave for å få toveis kommunikasjon, men ser for meg noen 433MHz enheter. Hva trenger jeg for å koble opp 433MHz enheter på egen maskin? Får jeg tak i 433MHz usb stick fra noen sted i norge?
  16. Heisann, jeg begynner så smått å automatisere hjemmet. På sikt vil lys, klima, dør og overvåking havne på samme plattform. Det kan hende jeg tvinges over på Homeseer etter hvert, men jeg begynner med Home assistant of tar det derfra. Per i dag har jeg kun Philips hue, nest protect og villavent (monterer i vinter, vsr500 med z-wave) Jeg ønsket å begynne enkelt, men ikke mure meg inn i et hjørne, så jeg ser for meg: Raspberry pi3 b+ Razberry v2 Home assistant. Kan jeg bruke hue bridge som zigbee kontroller, eller må jeg kjøpe ny kontroller? Er dette et greit utgangspunkt?
  17. Hei, Selger følgende HS3 lisenser: Og en HomeSeer Z-Net (Nypris 1690,- fra Intin.no februar 2017). Selges samlet for kr 2500 pluss frakt og 20$ til Homeseer for lisens overføring. Dette burde være et knalltilbud siden bare HS3 Pro koster 2500kr på 50% salg nå.
  18. FAQ låser til smartthings for oss i Norden. Mange lurer på dette med låser, og siden det reelt sett bare er et alternativ for oss her oppe så lagde jeg en faq i går, les om det er av interesse. 1 ID-lock med z-wave brikke er det støtte for både med default device handler fra smartthings og med utvidet funksjonssett i custom code. Anbefaler å gi noen dollar til rboy som du finner på community dot smartthings dot com så får du best mulig kode til låsen. Denne har 2 koder. 1 masterkode for familien, samt en en service kode som du kan skifte så ofte du vil. Om man bruker master til mor og far, og service til resten av familien osv bestemmer du naturligvis selv. Det medfølger 10 stk rfid brikker som er unike når man legger de inn. Med en smart app kan man endre koden på service kode. Brikker vs koder. Brikke nr 1 er automatisk masterkode brukeren, nr 2 er servicekode brukeren, nr 3-10 er unike uten mulighet for kode. Flere koder i fremtiden? Mulighet for å endre koder i forhold til tid? ID-Lock er ikke veldig informative på slikt, så min teori er at vi nok ikke på lang tid ser støtte for flere koder, ingen vits i å mase på dem heller for de svarer ikke uansett. Endre koder i forhold til tid? Eks åpent frem til 12 på fredag fordi da kommer det en murer. Dette kan du løse på mange måter, men tror at det å gjøre det manuelt i en smart app, eller på låsen blir det mest naturlige. Om du vil lage en schedule for at eks vaskehjelp kommer på torsdager etter 12:00 så lar jo det seg løse i core. Sette kode automatisk torsdag morgen, og endre den til noe annet på ettermiddagen i samme core script. Varslinger: Du kan få varsel om bruker 1, 2 , 3…. åpner, du kan få varsel om feil kode ble brukt, du kan få varsel om døra brenner (temperatur), varsel om døra er åpen eller lukket, du kan slå av alarmen om låsen åpnes… Det er ingen grenser for hva du kan få ut av data og gjøre noe med. 2 Yale i Norden er låst slik at z-wave modul for home brew ikke vil fungere, og Trioving har ingen planer om å endre dette, med overveiende sannsynlighet grunnet avtaler med alarmselskaper. Dette virker andre steder på kloden. 3 Det finnes et par andre alternativer som sikkert kan benyttes i blokker ol. Men som nok ikke er særlig gunstige å benytte på hoveddøra i Norsk klima.
  19. Har satt opp en Single Switch 2, som styrer 5 led spotter. Som bryter bruker jeg en dimmer. Har koblet opp iht. koblingsskjema. (Har fagbrev som elektriker og kan dermed utføre slike ting i mitt eget hjem), Når jeg slår på dimmer eller trykker på "b-knappen" så slår bare lysene seg på og så av igjen etter 1 sekund. Er det en form for mode jeg må endre?
  20. Del 3: Z-wave-håndtering Nå har vi valgt en HomeSeer-versjon, og vi har satt det opp slik at det i det minste sviver. Men HomeSeer trenger å snakke med omverdenen for å være til nytte. En protokoll til det er Z-wave. Forbehold: Dette er skrevet med HomeSeer-versjon 3.0.0.297 og Z-wave plugin-versjon 3.0.1.93. Deler av det som står her kan ha blitt endret senere. Veldig kort om Z-wave Z-wave er en protokoll som både kan sende og motta beskjeder. Hver Z-wave enhet kalles en node, utenom sjefs-noden som kalles master controller. Flere noder som snakker sammen og med samme master controller er et nettverk. Når en node mottar en beskjed ("skru lyset ditt på") så kvitteres det tilbake til master controller. For å justere et eller annet (f.eks. dimme-tid, følsomhet for bevegelsessensorer, etc) sendes en parameter til noden. Z-wave lager et såkalt "mesh nettverk". Nodene snakker med flere andre noder, og kan sende beskjeder videre fra en til en annen, og dermed har man sjeldent dekningsproblemer. Interface/controller Man trenger et interface slik at programvaren kan kommunisere med den virkelige verdenen. Hvis du har valgt en hardware-boks fra HomeSeer, så følger det med. Hvis du har valgt kun programvare, må du kjøpe et. Mange bruker UZB1 (versjon 5.2 kan med oppdateres), andre bruker Z-stick Gen 5. Disse kobles til maskinen via USB. Noen av oss bruker til og med Z-NET, et ethernet-interface fra HomeSeer (det er hendig hvis du kjører HomeSeer på en virtuell maskin, eller trenger å plassere interfacet et stykke fra serveren). Akkurat nå er det uansett viktig å sørge for at interfacet/controlleren (jeg bruker ordene litt om hverandre) støtter Z-wave Plus. Ellers kan det nevnes at UZB1 har en fordel over Z-stick: HomeSeer kan ta backup av UZB1 og "restore" den tilbake til den samme eller en annen controller/interface. Det er også mulig med Z-stick, men da må du bruke Aeon Labs egen Windows-programvare. Du har valgt et interface? Bra, da fortsetter vi med å legge det til i HomeSeer. Aller først sjekker vi at Z-wave plugin'en kjører. Det gjør vi ved å gå til Plugins → Manage. Når dette er gjort går du til Plugins → Z-wave → Controller Management. Se under overskriften "Z-wave Interfaces". Hvis du ser et interface der, så trykk på den gule pilen for konfigurasjon. Hvis ikke, trykk på knappen "Add Interface" (om du ser det ene eller det andre er versjonsavhengig, men begge deler gir det samme resultatet). Navngi den på en fornuftig måte (jeg har bare kalt den "UZB1"). Velg så riktig interface. Hvis du har en Zee2 med innebygget interface velger du dermed "Internal", har du UZB1 velger du "Z-wave.me UZB", har du Z-stick velger du "Aeon Labs Z-stick". Og så videre. Det siste er å velge riktig COM-port (hvis du ikke har et innebygget interface). I Windows kan du finne COM-porten i Device Manager (Windows-tast + X → Device Manager → COM-ports). Jeg er ingen Linux-expert, men jeg fant den som vist i bildet under: Når alt dette er gjort, trykker vi på det røde symbolet med gul bakgrunn øverst for å aktivere interfacet. Hvis alt nå er vel, endres teksten til "Initializing". Og deretter blir det røde symbolet grønt. Interface'et er "node 1" i nettverket. Voliá! Du kjører nå Z-wave. Gratulerer! Inkludering Men å kunne snakke et språk er jo litt kjedelig hvis det ikke er noen å snakke med! Så vi må legge til noen flere noder. Først en Fibaro Dimmer 2 (FGD-212). Først må du få en elektriker til å koble opp noden hvis det er en mikromodul til fast installasjon. Gå til Plugins → Z-wave → Controller Management, og utvid controlleren din (f.eks. "UZB") ved å trykke på pilen i den gule sirkelen. I nedtrekksmenyen velger du "Add/Include a Node". Trykk Start. Nå må vi aktivere "inkluder"-funksjonen på noden. Mange noder har en knapp du typisk skal trykke på 3 ganger for å sende en "NIF", en "Node Information Frame". Mikro-moduler fra Fibaro og Qubino har en knapp på selve enheten, men man kan også bruke den eksterne bryteren ("S1") til dette. Etter litt tenking, legger HomeSeer til noden. Som vi ser roter Fibaro det litt til for oss om endpoints (det er en lang historie, den korte er at Fibaro feilaktig rapporterer at den er en multi-endpoint enhet, altså rapporterer den et ekstra endpoint den ikke har). Det skal vi imidlertid fikse i del 4. Naviger så til View → Device Management, og a) trykk på knappen "Show all" under de fler-fargede knappene øverst til høyre, eller b) velg "Node 2" (eller hvilken node du nå legger til) i menyen "Floor". Da får vi opp alt vi har i HomeSeer til nå: Skrur vi av og på "Switch MultiLevel 1" skal lyset gå av og på. Ekskludering Ekskludering, det vil si fjerning av en node fra nettverket, er, som navnet tilsier, det omvendte av å inkludere en node. Og prosedyren er også tilsvarende enkel. Gå til Plugins → Z-wave → Controller Management. Utvid controlleren. Finn "Remove/Exclude a Node" i nedtrekksmenyen og trykk "Start". Aktiver "inkluder"-funksjonen på den fysiske enheten (trykk 3 ganger) på samme måte som når du la den til. Enheten fjernes nå fra nettverket. Optimalisering EDIT: Hvis du har et veldig stort nettverk, la oss si større enn 40-50 noder på fast strøm, så anbefales det ikke å optimalisere hele nettverket lenger. Optimaliser heller kun noen utvalgte (faste) noder. Så helt til slutt noe av det viktigste. Som nevnt innledningsvis er Z-wave et mesh-nettverk, flere noder kan kommunisere med hverandre. Men dermed må en ny node også finne ut hvilke noder som allerede finnes i nettverket. Til det må vi kjøre en "Optimize"-rutine (andre kaller det også "heal"). Hvis du allerede har et nettverk og kun har lagt til en ny node, så går du til den nye nodens root → Z-wave og trykker på knappen "Optimize" (1 gang). Hvis du får beskjed om at det var vellykket, så trykker du på knappen "Full Optimize" (1 gang). Hvis den også er vellykket, så er du ferdig! Hvis ikke, starter du på ny med "Optimize" igjen. Hvis du har lagt til mange noder, så kan du få HomeSeer til å optimalisere alle på en gang. Gå til Plugins → Z-wave → Controller Information. Under controlleren din velger du "Optimize a Network, No Return Route Changes" og trykker "Start". Hvis noen av nodene gir en feilmelding, kan du enten optimalisere nodene manuelt, eller du kan kjøre rutinen en gang til. Når alle nodene er ferdig optimalisert, skal vi gjøre det en gang til, men denne gangen velger vi "Fully Optimize a Network". Feiler noen av nodene må "Optimize" og "Full Optimize" kjøres pr feilet node. Merk: Erfarne HomeSeer-brukere, spesielt de som brukte HomeSeer 2, vet at tidligere var det snakk om at man skulle kjører "Optimize" hele 4 ganger før man kjørte "Full Optimize". Dette er ikke nødvendig lenger. Det holder med 1 gang. Bittelitt teori: "Optimize" for en node oppdager andre noder i nettverket den er i stand til å kommunisere med, og velger ut opptil 4 forskjellige ruter fra master til node som den lagrer. "Full Optimize" gjør det samme, men lagrer også den beste "retur-ruten" tilbake til master. Oppsummering Nå har du et kjørende Z-wave nettverk, med en eller flere noder. I del 4 skal vi se på litt enkel feilretting (i de tilfellene det er nødvendig), justering av parametere og bruk av assosiasjoner for å kontrollere noder. Tidligere har vi sett på valg mellom de ulike versjonene (del 1) og hvordan man setter det opp (del 2). I del 5 skal vi se nærmere på bruk av 433MHz-teknologi med RFXtrx433, og i del 6 det skal vi behandle alle enhetene våre, navngi dem, sortere, og se litt nærmere på mulighetene vi har i grensesnittet. Spørsmål? Kommentarer? Gi et pip i kommentarfeltet! Vis full oppføring
  21. Kurt Näslund

    Garasjeportåpneren

    Heisann 🙂 Jeg har en Chamberlain Motorlift 700 garasjeport med bryter for åpning, samt fjernkontroll. Hvordan kan jeg få denne til fjernstyres fra app da via en eller annen z-wave løsning? Mvh, Kurt Näslund Røros
  22. I HS3-loggen får jeg gjentatte oppføringer av mine to Fibaro multisensorer. Disse har flere temperaturfølere tilkoblet. Er det noen med forslag på hvordan dette kan minimeres? Har jeg satt opp dette galt? Kommer 20-30 oppføringer hver gang temperaturen endres.
  23. Bgam

    Bytte til Vera

    Hei! Jeg vurderer å gå til innkjøp av Vera, men er da viktig at den får til noen funksjoner jeg allerede har i huset. Mesteparten av funksjonene jeg har er stort sett manuelt skriptet i Lua, så ønsker egentlig at eventuelt ny kontroller skal være litt mer plug-n-play så jeg slipper å finne opp hjulet på nytt. Varmestyring: Varmestyringen er en kombinasjon av batteridrevne temp+bevegelse sensorer som styrer panelovner via wall-plug og heatit termostater for varmekabler/varmefolie. Komfort: Setpunkt settes til 21°C ved bevegelse i rom. Øko: Setpunkt reduseres med 2°C etter 2 timer uten bevegelse (i forhold til komfort-setpunkt). Nattsenking: Kalenderstyrt, setpunkt reduseres med 3°C (i forhold til komfort-setpunkt) Frostsikring/Feriemodus: Alle setpunkt settes til 12°C. Overstyrer alle andre moduser. Overvåking av wall-plugger: Hvis systemet ber om varme, men det blir oppdaget at wall-plug ikke har et effektforbruk 1. minutt etter at den skal ha slått seg på, så skal det sendes ut et OFF-ON signal til wall-plug. Lysstyring: Lys på ved bevegelse, automatisk av etter ønsket tidsintervall, har forskjellige tidsintervaller avhengig av hva slags rom det er. Når nattsenking er aktiv, skal lys i visse rom kun dimmes til 10% ved bevegelse. Slukkepuls for lys i garasje, hvis lyset er på i mer enn 5 timer sammenhengende skal det slå seg av automatisk. Div: Virtuell push-bryter i app til åpning av garasjeport. Integrasjon av kamera i app, benyttet for overvåking av garasjeporten. Monitoring av batterinivå til alle batteridrevne enheter, varsling på mail og i app hvis batterinivå til en enhet går til 0%. Monitoring av temperaturnivåer. Mail / Push-varsel hvis temperatur går under 5°C eller over 35°C. Alarm ved vannlekkasje. Forenklet alarmsystem. Varsel på mail ved bevegelse i huset når feriemodus er aktivert. Logging av temperaturer. Effektforbruk nå/dag/uke/måned. Har måler på inntakskabelen.
  24. Heisann, Har dere noen ideer til enklest mulig måte å integrere en analog inngang i Home Assistant? Sensoren jeg ønsker å integrere er følgende: https://www.westsystem.no/p/11202/tankgiver-s5---wema Denne har måleområde fra 0 til 180 Ohm. Giveren skal måle vannivået i en bekk på naboen sin tomt. Bekken går inn i ett rør som fortsetter under min tomt, og innløpet har en lei tendens til å tette seg med lau, søppel osv. Og vannet kommer da som en foss ned på min tomt.. Vil derfor lese av vanninået i HASS, og ha mulighet for varslinger ved høyt vannivå. -Slik at jeg kan ordne opp i innløpet før det går galt. Ønsker med fordel å lese av en analog verdi, så jeg hele tiden har kontroll på nivået. Jeg har vært litt inne på tanken med å bruke en Arduino med ESP8266 wifi modul. Og MQTT eller aRest til å få verdien inn i HASS. Men ettersom dette må settes opp ute, kreves det fort en litt stor boks osv. (estetisk). Finnes det noen enklere eller bedre måte å få dette til på? Noen som har noen ideer? Er selvsagt åpen for å benytte andre givere, men de må helst ha litt stort måleområde, opptil 1m. Det hadde vært en fordel å fått dette inn på Z-wave nettverket.
  25. Hei, Jeg og min samboer kjøpte leilighet for et halvt års tid siden, og jeg har endelig kommet litt i gang med Home Assistant igjen. Det finnes allerede en slags "smart" løsning her når det kommer til belysning, men den er dessverre av en type som ikke lar seg integrere i Home Assistant. I stue og kjøkken finnes det 27 downlights som jeg tror er av denne typen. De kan dimmes med løse brytere som vi har liggende (ser ut som en helt vanlig veggbryter bare at den ikke er fastmontert og har batteri på baksiden). Dette foregår via xComfort og dimmere i taket (jeg teller 4 punkter i taket hvor de ser ut til å ligge). Mitt største problem med dagens løsning er at det er et stygt grønnskjær i lyset som er særlig synlig nå som det begynner å bli mer mørkt ute. Jeg ønsker derfor å bytte ut alle pærer, og gjerne til en type med regulerbar fargetemperatur. Har sett litt på dim-to-warm typen og det virker aktuelt. Da tenker jeg at hvis alle pærer uansett skal byttes kan vi bruke en liten ekstra sum på å få byttet til et system som kan integreres med Home Assistant. En viktig detalj er at systemet bør helst fungere også uten Raspberry Pi, Home Assistant osv. Dette fordi vi planlegger å selge leiligheten igjen i løpet av noen år. I verste fall kan det følge med en slags hub, men vil helst unngå det også. Per i dag finnes det ingen fastmonterte brytere til lys i taket, så kanskje det enkleste blir nye batteridrevne brytere? Jeg lurer bare på hvilke alternativer jeg har her - og hva som kan lønne seg økonomisk sett. Z-Wave og Zigbee ser attraktivt ut, men jeg er veldig dårlig på det tekniske her og behøver som sagt råd. Takk for oppmerksomheten!
  • Medlemsstatistikk

    2 464
    Totalt antall medlemmer
    714
    Flest pålogget
    AndyB
    Nyeste medlem
    AndyB
    Ble med
×